The website uses cookies for smooth operation, improved browsing experience, marketing. More about cookies used and how to opt out it - Privacy policy

UNI-T UT210E Digital Clamp Meter, True RMS, AC/DC 100 A, 1 mA, NCV ATSR210E.jpg

UNI-T UT210E Digital Clamp Meter, True RMS, AC/DC 100 A, 1 mA, NCV

Code ATSR210E
  • Manufacturer UNI-T
  • Weight 320.00g

E-shop price: 55,00 €

Amount: 2+ 3+
Price: 53,35 50,31
Minimum order: 1 Repeatability : 1

Amount
Item location:
Central warehouse in Kaunas Item is not available (0)
Shop in Vilnius Item available (2)
Shop in Kaunas Item available (1)

Description

Datasheet User's manual

UNI-T UT210E Digital Clamp Meter, True RMS, AC/DC 100 A, 1 mA, NCV

The UNI-T UT210E is a compact digital clamp meter designed to measure alternating (AC) and direct (DC) current up to 100 A without disconnecting the conductor. It also provides multimeter functions for voltage, resistance, capacitance, diode testing and continuity checking. True RMS measurement, 1 mA resolution on the lowest current range and non-contact voltage detection (NCV) make it a practical instrument for electrical installation, equipment maintenance and electronic troubleshooting.

Key specifications: AC/DC current up to 100 A • 1 mA resolution • True RMS • AC/DC voltage up to 600 V • NCV • CAT III 300 V / CAT II 600 V

Key Features and Benefits

  • AC/DC clamp current measurement – measures current flowing through a conductor without opening the electrical circuit, supporting both AC and DC applications.
  • 1 mA current resolution – the 2 A range provides detailed readings of relatively small current changes. Resolution should not be confused with guaranteed measurement accuracy.
  • True RMS measurement – provides true root mean square readings of AC voltage and current, improving measurement of non-sinusoidal waveforms within the specified operating limits.
  • VFC measurement mode – provides filtered AC voltage and current measurements for applications involving variable-frequency drives.
  • Integrated multimeter functions – measures AC/DC voltage up to 600 V, resistance up to 20 MΩ and capacitance up to 20 mF, with diode and continuity testing.
  • Non-contact voltage detection (NCV) – uses audible and visual indications to detect an AC electric field without direct contact with a conductor's metal surface.
  • ZERO/REL function – enables DC current zero adjustment and relative measurements.
  • Automatic ranging – simplifies voltage, resistance and other supported measurements; current ranges are selected manually.
  • Backlit LCD and data hold – improve readability in poorly illuminated areas and allow the displayed measurement to be retained.
  • Compact 17 mm clamp jaw – suitable for electrical panels and installations where working space is limited.

Applications

The UNI-T UT210E is suitable for electrical installation checks, maintenance of electrical equipment, automotive and other low-voltage DC system diagnostics, and electronics troubleshooting.

Typical applications include checking electrical equipment current consumption, measuring power supply voltage, testing wiring continuity, measuring resistor values and checking capacitors.

Its DC current measurement function is particularly useful for battery-powered equipment, DC power supplies and other direct-current circuits within the instrument's measurement and safety limits.

The meter is suitable for DIY users, electricians, maintenance technicians and electronics specialists requiring a compact, versatile measuring instrument.

Compatibility and Limitations

  • Clamp current measurements require a single conductor inside the jaws. Clamping around both live and neutral conductors simultaneously may result in magnetic field cancellation.
  • Maximum conductor diameter: 17 mm.
  • Maximum current measurement: 100 A AC/DC.
  • Maximum voltage measurement: 600 V AC/DC, subject to CAT II 600 V / CAT III 300 V measurement category restrictions.
  • AC current frequency response: 50–60 Hz; AC voltage frequency response: 45–400 Hz.
  • No temperature measurement function or dedicated frequency measurement mode.
  • NCV is an auxiliary detection function and must not be used to verify that a circuit is de-energized.
  • The instrument does not directly measure electrical power or energy consumption.

Technical Specifications

Parameter Specification
Manufacturer UNI-T
Model UT210E
Instrument type Digital AC/DC clamp meter with multimeter functions
Measurement technology True RMS
Display counts 2000
Sampling rate 2–3 readings/s
AC current ranges 2 A / 20 A / 100 A
DC current ranges 2 A / 20 A / 100 A
AC current resolution 1 mA / 10 mA / 100 mA
DC current resolution 1 mA / 10 mA / 100 mA
AC current accuracy, 2 A ±(3% + 10 digits)
AC current accuracy, 20 A ±(2.5% + 8 digits)
AC current accuracy, 100 A ±(2.5% + 5 digits)
DC current accuracy, 2 A ±(2% + 8 digits)
DC current accuracy, 20 A / 100 A ±(2% + 3 digits)
AC current frequency response 50–60 Hz
DC voltage ranges 200 mV / 2 V / 20 V / 200 V / 600 V
AC voltage ranges 2 V / 20 V / 200 V / 600 V
DC voltage resolution 0.1 mV / 1 mV / 10 mV / 100 mV / 1 V
AC voltage resolution 1 mV / 10 mV / 100 mV / 1 V
DC voltage accuracy, 200 mV ±(0.7% + 5 digits)
DC voltage accuracy, other ranges ±(0.7% + 3 digits)
AC voltage accuracy, 2–200 V ±(1% + 3 digits)
AC voltage accuracy, 600 V ±(1.2% + 3 digits)
AC voltage frequency response 45–400 Hz
Voltage input impedance Approximately 10 MΩ
Resistance ranges 200 Ω / 2 kΩ / 20 kΩ / 200 kΩ / 2 MΩ / 20 MΩ
Resistance accuracy, up to 200 kΩ ±(1% + 2 digits)
Resistance accuracy, 2–20 MΩ ±(1.2% + 3 digits)
Capacitance ranges 2 nF / 20 nF / 200 nF / 2 µF / 20 µF / 200 µF / 2 mF / 20 mF
Capacitance accuracy, 2 nF ±(4% + 10 digits)
Capacitance accuracy, 20 nF – 200 µF ±(4% + 5 digits)
Capacitance accuracy, 2–20 mF ±10%
Continuity test Audible indication at resistance ≤10 Ω
Diode test Yes, approximately 3.2 V test voltage
NCV Non-contact AC electric field detection
VFC Filtered AC voltage/current measurement mode
ZERO/REL Zero adjustment / relative measurement
Auto ranging Yes, except current ranges
Data hold Yes
Display backlight Yes
Automatic power-off After approximately 15 minutes
Low battery indication Yes
Jaw opening 17 mm
Measurement category CAT II 600 V / CAT III 300 V
Safety standards EN 61010-1, IEC 61010-2-032, IEC 61010-2-033
Insulation Double insulation
Pollution degree 2
Operating temperature 0–40 °C
Storage temperature −10–50 °C
Maximum operating altitude 2000 m
Power supply 2 × 1.5 V AAA (R03)
LCD dimensions 39.3 × 26.5 mm
Product dimensions 175 × 60 × 33.5 mm
Weight Approximately 170 g

Accuracy note: Accuracy is expressed as ±(% of reading + least significant digits) at an ambient temperature of 23 ± 5 °C. Additional conditions apply to AC measurements, including signal frequency and waveform. Accuracy in VFC mode differs from normal measurement mode.

Design and Controls

The UT210E features a rotary function selector, clamp jaw trigger, digital LCD and dedicated SELECT, ZERO and HOLD buttons.

The SELECT button switches between associated measurement functions and provides access to VFC mode. ZERO is used to compensate DC current offset, while HOLD freezes the displayed reading. Pressing and holding HOLD activates or deactivates the display backlight.

Separate COM and positive input terminals are provided for voltage, resistance, capacitance and diode measurements.

Important Safety and Operating Notes

  • Before DC current measurement, use the ZERO function and maintain a similar instrument orientation during zero adjustment and measurement.
  • Disconnect test leads from the meter when measuring current with the clamp jaws.
  • Disconnect power and discharge capacitors before resistance, capacitance, diode or continuity measurements.
  • Do not exceed the specified measurement limits or safety categories.
  • For non-sinusoidal signals, additional True RMS measurement error may occur depending on waveform crest factor.
  • NCV response depends on conductor position, distance and electric field strength. Always verify absence of voltage using a suitable approved testing instrument.

Package Contents

  • UNI-T UT210E digital clamp meter
  • Test lead set
  • 2 × AAA 1.5 V batteries
  • Carrying pouch

Specification