The website uses cookies for smooth operation, improved browsing experience, marketing. More about cookies used and how to opt out it - Privacy policy

UNI-T UT58C Digital Multimeter, 1000 V DC, 20 A, Temperature and Frequency ATS58C.jpg

UNI-T UT58C Digital Multimeter, 1000 V DC, 20 A, Temperature and Frequency

Code ATS58C
  • Manufacturer UNI-T
  • Weight 570.00g

E-shop price: 46,95 €

Amount: 2+ 3+
Price: 44,60 41,29
Minimum order: 1 Repeatability : 1

Amount
Item location:
Central warehouse in Kaunas Item is not available (0)
Shop in Vilnius Item is not available (0)
Shop in Kaunas Item is not available (0)

Description

User's manual

UNI-T UT58C Digital Multimeter, 1000 V DC, 20 A, Temperature and Frequency

UNI-T UT58C is a manual-ranging digital multimeter designed for general electrical and electronics measurements. It measures AC/DC voltage and current, resistance, capacitance, frequency and temperature, and also provides diode, continuity and transistor hFE testing. Its large 60 × 54 mm LCD, Data Hold function and test-lead connection indication make routine measurements easier.

Key specifications:
DC up to 1000 V • AC up to 750 V • AC/DC current up to 20 A • -40...+1000 °C • frequency up to 20 kHz • 1999 counts

Key features and benefits

  • Wide range of electrical measurements – measures DC/AC voltage, DC/AC current and resistance for general electrical and electronic troubleshooting.
  • Capacitance measurement up to 100 µF – suitable for checking capacitors; in the 100 µF range, readings at ≥40 µF are specified by the manufacturer as reference only.
  • Temperature measurement from -40 °C to +1000 °C – supports K-type thermocouples. The supplied point-contact temperature probe is intended for measurements up to 230 °C.
  • Frequency measurement up to 20 kHz – 2 kHz and 20 kHz ranges are provided for low-frequency electronic signals.
  • 20 A AC/DC current range – enables short-duration high-current measurements; measurements at 20 A are limited to 10 seconds with an interval of more than 15 minutes between measurements.
  • Diode and continuity testing – the buzzer sounds continuously at ≤10 Ω and does not sound at >70 Ω.
  • Transistor hFE test – allows approximate checking of bipolar transistor current gain using the multi-purpose socket.
  • Data Hold – freezes the displayed measurement value for convenient reading.
  • Manual ranging – allows the user to select the required range and resolution directly.
  • Overload protection and lead-connection indication – provides manufacturer-specified input protection and visual guidance for test-lead connections.

Applications

The UNI-T UT58C is suitable for electrical and electronics troubleshooting, household electrical checks, component testing, repair and maintenance work, education and general laboratory measurements.

It is particularly useful when temperature, capacitance, frequency, diode or transistor testing is required in addition to standard voltage, current and resistance measurements.

Compatibility and limitations

  • Measurement ranges are selected manually; the meter does not provide autoranging.
  • AC measurement uses an average-responding (AVG) method calibrated to the RMS value of a sine wave; it is not a True RMS meter.
  • AC voltage frequency response: 40 Hz–1 kHz below 500 V and 40 Hz–400 Hz above 500 V.
  • AC current frequency response: 40 Hz–400 Hz.
  • 20 A AC/DC measurements are limited to 10 seconds, with more than 15 minutes between measurements.
  • During current measurements, the open-circuit voltage between the measurement points and ground must not exceed 250 V.
  • The supplied K-type point-contact probe is intended for temperatures up to 230 °C. A suitable K-type probe is required to use the full -40...+1000 °C meter range.
  • No True RMS, autoranging, Bluetooth or USB data interface.

Technical specifications

Parameter Specification
Instrument type Digital multimeter, manual ranging
Maximum display 1999 counts
Update rate 2–3 times/s
DC voltage 200 mV / 2 V / 20 V / 200 V / 1000 V
DC voltage resolution 0.1 mV / 1 mV / 10 mV / 100 mV / 1 V
DC voltage accuracy, 200 mV–200 V ±(0.5% of reading + 1 digit)
DC voltage accuracy, 1000 V ±(0.8% + 2 digits)
Voltage input impedance Approx. 10 MΩ
AC voltage 2 V / 20 V / 200 V / 750 V
AC voltage resolution 1 mV / 10 mV / 100 mV / 1 V
AC voltage accuracy, 2–200 V ±(0.8% + 3 digits)
AC voltage accuracy, 750 V ±(1.2% + 3 digits)
AC voltage frequency response 40 Hz–1 kHz (<500 V); 40 Hz–400 Hz (>500 V)
AC measurement method AVG response, sine-wave RMS indication
DC current 2 mA / 200 mA / 20 A
DC current resolution 1 µA / 0.1 mA / 10 mA
DC current accuracy, 2 mA ±(0.8% + 1 digit)
DC current accuracy, 200 mA ±(1.5% + 1 digit)
DC current accuracy, 20 A ±(2% + 5 digits)
AC current 2 mA / 200 mA / 20 A
AC current resolution 1 µA / 0.1 mA / 10 mA
AC current accuracy, 2 mA ±(1.0% + 3 digits)
AC current accuracy, 200 mA ±(1.8% + 3 digits)
AC current accuracy, 20 A ±(3.0% + 5 digits)
AC current frequency response 40 Hz–400 Hz
Resistance 200 Ω / 2 kΩ / 20 kΩ / 2 MΩ / 20 MΩ
Resistance resolution 0.1 Ω / 1 Ω / 10 Ω / 1 kΩ / 10 kΩ
Resistance accuracy, 200 Ω ±(0.8% + 3 digits) + test-lead short-circuit resistance
Resistance accuracy, 2 kΩ and 20 kΩ ±(0.8% + 1 digit)
Resistance accuracy, 2 MΩ and 20 MΩ ±(1.0% + 2 digits)
Capacitance 2 nF / 200 nF / 100 µF
Capacitance resolution 1 pF / 0.1 nF / 0.1 µF
Capacitance accuracy, 2 nF and 200 nF ±(4.0% + 3 digits)
Capacitance accuracy, 100 µF ±(5.0% + 4 digits); ≥40 µF reading is for reference only
Capacitance test frequency Approx. 400 Hz
Frequency 2 kHz / 20 kHz
Frequency resolution 1 Hz / 10 Hz
Frequency accuracy ±(1.5% + 5 digits)
Frequency input amplitude >100 mVrms and <30 Vrms
Temperature -40...+1000 °C
Temperature resolution 1 °C
Accuracy, -40...0 °C ±(3% + 7 digits)
Accuracy, 0...400 °C ±(1% + 3 digits)
Accuracy, 400...1000 °C ±2.5%
Temperature sensor K-type thermocouple
Diode test 1 mV resolution; open-circuit voltage approx. 3 V
Continuity Buzzer at ≤10 Ω; no buzzer at >70 Ω
Transistor test hFE, 1 β resolution, up to 1000 β
Data Hold Yes
Auto power-off / Sleep Mode Yes
Low-battery indication Yes
Polarity indication Automatic
Overload indication “1”
Test-lead connection indication Yes
mA input fuse 0.5 A / 250 V fast, 5 × 20 mm (CE version)
Safety category CAT II 1000 V / CAT III 600 V
Safety standard IEC 61010, Pollution Degree 2, double insulation
Certificates CE, RoHS
Operating temperature 0...40 °C
Storage temperature -10...+50 °C
Relative humidity ≤75% RH at 0...30 °C; ≤50% RH at 30...40 °C
Power supply 1 × 9 V battery, 6F22 / NEDA1604 / 006P
LCD size 60 × 54 mm
Product dimensions 179 × 88 × 39 mm
Net weight 350 g

Specified accuracy applies at 18–28 °C and up to 75% RH and is expressed as ±(% of reading + digits).

Construction and controls

The UT58C features a large 60 × 54 mm LCD, rotary function/range selector, separate POWER button and HOLD button. The display provides function symbols, polarity indication, low-battery indication and test-lead connection guidance.

A protective holster helps protect the instrument against normal mechanical impacts during transport and use.

Important safety and operating notes

  • Designed to IEC 61010 requirements for CAT II 1000 V / CAT III 600 V, Pollution Degree 2 and double insulation.
  • Do not attempt to measure voltages above 1000 V.
  • Extra caution is required above 60 V DC or 30 V RMS AC due to electric shock hazard.
  • Disconnect circuit power and discharge high-voltage capacitors before resistance, capacitance, diode or continuity testing.
  • Before current measurements, switch off circuit power and check the meter fuse.
  • At 20 A, measure for no more than 10 seconds and allow more than 15 minutes between measurements.
  • Replace the battery when the low-battery indicator appears, as a weak battery may cause incorrect readings.

Package contents

  • UNI-T UT58C digital multimeter;
  • pair of test leads;
  • multi-purpose measurement socket / adapter;
  • K-type point-contact temperature probe;
  • protective holster;
  • 9 V battery.

Specification